When battery fires strike, every second counts. The RFC Battery extinguishing system from fourobot delivers rapid thermal runaway mitigation through our Detachable EV Cooling Module. Engineered with 10 years of manufacturing expertise, this system combines water mist technology with optional Potassium Oxide Aerosol (POE) coverage—each section handles 4m³ of space while weighing just 9.3kg. You get 100 units in stock, 20-day production cycles for custom orders, and 5×12 hour response times. With CE and ISO certifications, our modular design stops battery fires before they escalate, protecting your vehicles, storage facilities, and personnel.

You can't afford delays during battery thermal events. Our RFC Battery extinguishing system is designed for one-person operation. Each lightweight module deploys in under 60 seconds. Simply connect the push rod, slide it beneath the burning vehicle, and activate water flow. The inverted umbrella spray pattern immediately targets overheated battery packs with cooling water mist.
Need more coverage? Connect multiple sections instantly. The quick-connection design extends your fire control area without complex setup. Whether you're tackling a single EV or a containerized battery storage unit, you scale protection to match the threat level.
Water mist cools surfaces and absorbs heat rapidly. Add the optional POE extinguisher for flame suppression in confined spaces. This combination addresses both thermal management and active fire control, giving you two layers of defense in one deployable system.
| Item | Specification |
|---|---|
| Dimension | L1100×W300×H130mm |
| Weight | 9.3kg |
| Material | Steel |
| Extinguisher Types | Water |
| Rated Work Pressure | 0.8 MPa (8kg/c㎡) |
| Work Pressure Range | 0.6–1.0 MPa |
| Nos of Sprinklers/Section | 6 Pcs |
| Spray Mode | Water Mist |
| Rated Water Flow | ≤0.3L/s (18L/min) |
| Total Space Coverage | ≥4m³ @0.8MPa |
| Wheels | Omni Wheels on triangle frame |
| Water Inlet Connector | DN40 × 1 |
| Water Outlet Connector | DN40 × 1 |
| Item | Specification |
|---|---|
| Dimension | L230×W280×H130mm |
| Weight | 2.3kg |
| Material | Steel |
| Water Inlet Connector | DN65 × 1 |
| Water Outlet Connector | DN40 × 1 |
| Item | Specification |
|---|---|
| Dimension | L200×W70×H160mm |
| Weight | 1.1kg |
| Water Inlet Connector | DN40 × 1 |
| Water Outlet Connector | DN40 × 1 |
| Item | Specification |
|---|---|
| Dimension | L3070×D36mm (3 rods connected) |
| Weight | 2.0kg |
| Material | Fiberglass |
| Insulation Voltage | 10kV |
| Item | Specification |
|---|---|
| Dimension | L115×W50×H40mm |
| Weight | 0.25kg/Pc |
| Nos of POE/Section | 2 Pcs |
| Ignition Temperature | ≥180℃ ±5℃ |
| Emission Duration | ≤30s |
| Total Space Coverage | ≥2m³ |
At just 9.3kg per section, one firefighter carries and deploys the entire module. You eliminate the need for heavy machinery or multiple personnel. Your team responds faster and retrieves equipment quickly after incidents.
We've refined our production process over 10 years. Every unit undergoes rigorous quality checks before shipping. You receive products that meet CE and ISO international standards, ensuring reliability in critical situations.

Work independently with the push rod RFC Battery extinguishing system or integrate with robotic fire suppression platforms. Our Water Inlet Connector B allows seamless connection to automated firefighting robots, expanding your tactical options.
We maintain 100 units in stock for immediate shipment. Custom orders ship within 20 days for quantities between 1-10 units. You get equipment when you need it, not weeks later.
Need specific configurations? We offer ODM/OEM services tailored to different regulatory environments and operational needs. Whether you require modified connectors, specialized spray patterns, or custom dimensions, we adapt to your specifications.

Electric Vehicle Incidents: Deploy under burning EVs at charging stations, parking structures, or roadside emergencies. The 4cm ground clearance fits most vehicle undercarriages.
Battery Storage Facilities: Protect containerized energy storage systems and grid-scale battery installations from thermal propagation.
Emergency Escape Routes: Create isolated fire barriers using water mist curtains, ensuring safe evacuation paths for personnel.
You're not alone after purchase. Our 1-year warranty covers manufacturing defects. Global local agents provide timely support in your region. We respond to technical inquiries within 5×12 hours, keeping your operations running smoothly.
Competitive pricing doesn't mean compromised quality. You get enterprise-grade fire suppression without enterprise-level expenses. Fast delivery and efficient communication reduce your total cost of ownership.

A:You can deploy a single section in under 60 seconds. The lightweight design and omni-directional wheels allow rapid positioning. Simply connect your water source, attach the push rod, slide it beneath the vehicle, and activate water flow.
A:Basic training takes 30-45 minutes. We provide operation manuals and can arrange remote training sessions. The intuitive design minimizes learning curves—if your team can operate a standard fire hose, they can use this system.
A:Absolutely. The water mist approach cools battery cells without causing electrical shorts or violent chemical reactions. The 10kV insulated push rod protects operators from electrical hazards during deployment.
A:Every standard package includes the Water Mist System, Water Inlet Connector A and B, and the three-section Push Rod. The POE extinguisher is optional and can be added based on your fire suppression strategy.
A:Traditional foam creates cleanup challenges and may not penetrate battery pack enclosures effectively. Our water mist system delivers targeted cooling directly to heat sources. It's cleaner, faster to deploy, and specifically designed for modern battery fire scenarios.
A:Inspect wheel assemblies and connectors quarterly. Check hose connections for wear. The steel construction resists corrosion, but we recommend storing units in dry environments. No special certifications are needed for routine maintenance.
A:Yes. The quick-connection design allows you to link multiple sections within seconds. This extends coverage area and increases cooling capacity for large-scale battery fires or multiple-vehicle incidents.
A:We offer air, sea, and land transportation options worldwide. Our logistics team coordinates customs documentation and ensures compliance with international shipping regulations. Contact us for specific delivery timeframes to your location.
Contact our team at sales@fourobot.com to discuss your requirements for RFC Battery extinguishing system and receive a detailed quotation.
Learn about our latest products and discounts through SMS or email